Standard gas configuration
DrägerSensor Measuring
range
1)
Alarm A1
1)
Alarm A2
1)
setpoint
can be
acknowledged
self-latching
setpoint
can be
acknowledged
self-latching
CatEx 125 PR
[%LEL]
0 to 100 20 Yes No 40 No Yes
CatEx 125 PR Gas
[%LEL]
0 to 100 20 Yes No 40 No Yes
XXS O
2
[vol. %] 0 to 25 19
2)
No Yes 23 No Yes
XXS O
2
100 [vol. %] 0 to 100 18.5
2)
No Yes 24 No Yes
XXS O
2
LS / CO-LC
[vol. %], [ppm]
0 to 25 O
2
0 to 2000 CO
19 O
2
30 CO
No
Yes
Yes
No
23 O
2
60 CO
No
No
Yes
Yes
XXS O
2
/ H
2
S-LC
[Vol%], [ppm]
0 to 25 O
2
0 to 100 H
2
S
19 O
2
5H
2
S
No
Yes
Yes
No
23 O
2
10 H
2
S
No
No
Yes
Yes
XXS CO [ppm] 0 to 2,000 30 Yes No 60 No Yes
XXS CO LC [ppm] 0 to 2,000 30 Yes No 60 No Yes
XXS CO-LC/H
2
S-LC
[ppm]
0 to 2,000
0 to 100
30
5
Yes
Yes
No
No
60
10
No
No
Yes
Yes
XXS CO-LC/O
2
[ppm], [vol.-%]
0 to 2,000 CO
0 to 25 O
2
30 CO
19 O
2
Yes
No
No
Yes
60 CO
23 O
2
No
No
Yes
Yes
XXS CO HC [ppm] 0 to 10,000 600 Yes No 1,200 No Yes
XXS CO H
2
-CP [ppm] 0 to 2.000 30 Yes No 60 No Yes
XXS H
2
[ppm] 0 to 2.000 200 Yes No 400 No Yes
XXS H
2
S [ppm] 0 to 200 5 Yes No 10 No Yes
XXS H
2
S LC [ppm] 0 to 100 5 Yes No 10 No Yes
XXS H
2
S HC [ppm] 0 to 1,000 10 Yes No 20 No Yes
XXS H
2
S/CO [ppm] 0 to 200 H
2
S
0 to 2,000 CO
5 H
2
S
30 CO Yes No
10 H
2
S
60 CO No Yes
XXS H
2
S-LC / CO-LC
[ppm]
0 to 100 H
2
S
0 to 2000 CO
5 H
2
S
30 CO
Yes
Yes
No
No
10 H
2
S
60 CO
No
No
Yes
Yes
XXS NO [ppm] 0 to 200 25 Yes No 50 No Yes
XXS NO
2
[ppm] 0 to 50 5 Yes No 10 No Yes
XXS SO
2
[ppm] 0 to 100 0,5 Yes No 1 No Yes
XXS PH
3
[ppm] 0 to 20 0.1 Yes No 0.2 No Yes
XXS PH
3
HC [ppm] 0 to 2,000 5 Yes No 10 No Yes
XXS HCN [ppm] 0 to 50 1.9 Yes No 3.8 No Yes
XXS HCN PC [ppm] 0 to 50 5 Yes No 10 No Yes
XXS NH
3
[ppm] 0 to 300 20 Yes No 40 No Yes
XXS CO
2
[vol. %] 0 to 5 0.5 Yes No 1 No Yes
XXS Cl
2
[ppm] 0 to 20 0.5 Yes No 1 No Yes
XXS H
2
HC [vol. %] 0 to 4 0.8 Yes No 1.6 No Yes