EasyManuals Logo

Draytek Vigor2960 series User Manual

Draytek Vigor2960 series
446 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #291 background imageLoading...
Page #291 background image
Vigor2960 Series User’s Guide
283
Enabling firewall applications on your PC may cause the UPnP function not working
properly. This is because these applications will block the accessing ability of some
network ports.
Security Considerations
Activating the UPnP function on your network may incur some security threats. You
should consider carefully these risks before activating the UPnP function.
Some Microsoft operating systems have found out the UPnP weaknesses and hence
you need to ensure that you have applied the latest service packs and patches.
Non-privileged users can control some router functions, including removing and
adding port mappings.
The UPnP function dynamically adds port mappings on behalf of some UPnP-aware
applications. When the applications terminate abnormally, these mappings may not be
removed.
4
4
.
.
8
8
.
.
5
5
H
H
i
i
g
g
h
h
A
A
v
v
a
a
i
i
l
l
a
a
b
b
i
i
l
l
i
i
t
t
y
y
The High Availability (HA) feature refers to the awareness of component failure and the
availability of backup resources. The complexity of HA is determined by the availability
needs and the tolerance of system interruptions. Systems, provide nearly full-time
availability, typically have redundant hardware and software that make the system available
despite failures.
The high availability of the Vigor2960 Series is designed to avoid single points-of-failure.
When failures occur, the failover process moves processing performed by the failed
component (the “Master”) to the backup component (the “Slave”). This process remains
system-wide resources, recovers partial of failed transactions, and restores the system to
normal within a matter of microseconds.
Take the following picture as an example. The upper Vigor2960 is regarded as Master
(Active) device, the lower Vigor2960 is regarded as Slave (standby) device. When Master
Vigor2960 Series is broken down, the Slave device could replace the Master role to take
over all jobs as soon as possible. However, once the original Master is working again, the
Slave would be changed to original role to stand by.

Table of Contents

Other manuals for Draytek Vigor2960 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Draytek Vigor2960 series and is the answer not in the manual?

Draytek Vigor2960 series Specifications

General IconGeneral
BrandDraytek
ModelVigor2960 series
CategoryFirewall
LanguageEnglish

Related product manuals