32
[018]
Option
6
Burglary Verification ON Cross Zoning is Enabled. The panel will use the Cross Zone Attribute for Burglary Ver-
ification.
This feature requires two or more trips on a zone(s) specified as “cross zones” within a
specified time before starting an alarm sequence. See Section [101],Option 9, Pg 33.
When a zone with the Cross Zone Attribute Enabled is violated, nothing occurs on the
local premises (except Entry Delay, if applicable) and the Cross Zone Timer commences. If
another Zone with the Cross Zone attribute enabled is violated before the timer expires,
the panel will transmit the first alarm signal, a Cross Zone event , followed by the second
zone alarm, and begins the appropriate local alarm sequence. If no other zones are vio-
lated before the timer the expires, no alarm sequence occurs and an Alarm Not Verified
event is logged. If the Double Hit Feature is enabled (Section [017], Option 4), the panel
will react on two violations of the same zone during the Cross Zone Timer (Section [176])
for starting an alarm sequence.
This option is dependent on the programming of the Burglary Verification Options (Sec-
tion [018], Option 6). It is not enabled if Police Code is enabled.
This option will not function on zones that do not log alarm events (e.g. While disarmed,
Day Zone, Instant zone, etc.)
NOTE: The Cross Zone/Police Code Timer is in Seconds for Cross Zoning and in Minutes
for Police Code.
NOTE: No fire zones types should use the Cross Zone Attribute.
OFF Police Code is Enabled. The panel will use the Police Code feature for Burglary Verifica-
tion. This option is OFF at default.
[018]
Option
7
Exit Delay Restart ON One Time Exit Delay Restart on Delay zone re-entry Enabled. If a Delay zone is vio-
lated and restored during the Exit Delay, it is considered an exit. If a delay zone is violated
again it is considered a re-entry. With this option enabled the panel will restart the exit
delay. Further violations and restores of delay zones will not restart the exit delay.
OFF One Time Exit Delay Restart on Delay zone re-entry Disabled. Delay zone violations
and restores will not restart the exit delay.
NOTE: The exit delay can only be restarted once. This includes restarts from Away func-
tion keys.
Section Option On/Off Description