[381] - Second Communicator Option Codes
[381] - SECOND COMMUNICATOR OPTION CODES
Option Communicator Code On/Off Description
1 Opening After Alarm Key-
pad Ringback
ON Opening After Alarm Keypad Ringback Enabled. When the Opening After Alarm
reporting code is successfully transmitted to a programmed telephone number, the key-
pad will sound a series of 8 beeps to confirm to the end user that the Opening After
Alarm Code was sent and received. This Ringback will occur for each Opening After Alarm
code successfully reported.
OFF Opening After Alarm Keypad Ringback Disabled
2 Opening After Alarm Bell
Ringback
ON Opening After Alarm Bell Ringback Enabled. When the Opening After Alarm report-
ing code is successfully transmitted to a programmed telephone number, the Bell will
sound a series of 8 squawks to confirm to the end user that the Opening After Alarm
Code was sent and received. This Ringback will occur for each Opening After Alarm code
successfully transmitted.
OFF Opening After Alarm Bell Ringback Disabled
3 SIA Reporting Codes ON SIA Sends Programmed Rep. Codes. This option is for use with the SIA communication
format.). If 00 is programmed in the reporting code section, the event will not be commu-
nicated. When this option is ON and there is a valid reporting code programmed in the
reporting code section, the programmed reporting code will be transmitted. If FF is pro-
grammed as a reporting code, the event will not be communicated.
Reporting Code Entry Option ON Option OFF
00 No Transmission No Transmission
FF No Transmission Auto Rep Code sent
01-FE 01-FE sent Auto Rep Code sent
OFF SIA Sends Automatic Rep. Codes. When this option is OFF and there is a valid reporting
code (01-FE) or FF programmed in the reporting code section, the panel will transmit an
automatic reporting code for SIA only. This would be used when automatic reporting
codes are required but there is a requirement for a different reporting code (i.e. Pager For-
mat, etc.).
4 Closing Confirmation ON Closing Confirmation Enabled. When a Closing reporting code is successfully transmit-
ted to a programmed telephone number, the keypad will sound a series of 8 beeps to
confirm to the end user that the Closing Code was sent and received.
OFF Closing Confirmation Disabled. There will be no keypad ringback when a Closing
reporting code is successfully transmitted to a programmed telephone number.
5 Talk/Listen Options for
Phone Number One/Three
ON Talk/Listen (PC5936) on Phone #1/3 Enabled. If Talk/Listen is requested for an event by
the PC5936, the panel will request the session on the next communication on Phone
Number 1/3 to the central station.
OFF Talk/Listen (PC5936) on Phone #1/3 Disabled. The panel will not request a Talk/Listen
session for an event even if the PC5936 has requested it.
6 Talk/Listen Options for
Phone Number Two
ON Talk/Listen (PC5936) on Phone #2 Enabled. If Talk/Listen is requested for an event by
the PC5936, the panel will request the session on the next communication on Phone
Number 2 to the central station.
OFF Talk/Listen (PC5936) on Phone #2 Disabled. The panel will not request a Talk/Listen
session for an event even if the PC5936 has requested it.
7 Contact I.D. Reporting
Codes
ON Contact I.D. Uses Programmed Reporting Codes. The Contact I.D. communications
format will use programmed reporting codes when transmitting to central station.
OFF Contact I.D. Uses Automatic Reporting Codes. The Contact I.D. communications for-
mat will use the automatic reporting codes as shown in Appendix C when transmitting to
central station.
8 Local Mode ON Local Mode Enabled. The panel will always send events to the PC5108L Module. Down-
look will not be initiated if requested.
OFF Local Mode Disabled. The panel will only send events that are being communicated to
the PC5108L Module. Downlook will be initiated when requested.
[382] - THIRD COMMUNICATOR OPTION CODES
Option Communicator Code On/Off Description
1 Contact I.D. Partial Closing
Identifier
ON Partial Closing Identifier = 5. Contact I.D. uses ‘5’ as the Identifier for the Partial Clos-
ing event.
OFF Partial Closing Identifier = 4. Contact I.D. uses ‘4’ as the Identifier for the Partial Clos-
ing event. This option is defaulted OFF.
2 Walk Test Communication ON Zone Alarms Communicate during Walk Test Enabled. Zone alarms that occur during
Walk Test will communicate if programmed to do so.
OFF Zone Alarms Communicate during Walk Test Disabled. Zone alarms that occur dur-
ing Walk Test will not communicate even if programmed.This option is defaulted OFF.