Programming Sections: 5.8 Programmable Output Programming
49
[401] - First Downloading Option Codes
[402] - Downloading Computer’s Telephone Number
This telephone number is 32 digits in length.
[403] - Downloading Access Code
This 4-digit Hexadecimal code allows the panel to confirm that it
is communicating with a valid downloading computer.
[404] - Panel Identification Code
This 4-digit Hexadecimal code allows the downloading computer
to confirm the identity of the control panel.
[405] - Double-Call Timer
This timer sets the amount of time that can be taken between
calls when using Double Call to contact the panel.
Valid entries are 001 to 255 (seconds)
[406] - Number of Rings to Answer On
The value in this section determines how many rings that the panel
will automatically pick up on in order to establish a DLS connection.
Default value is 000 rings. Valid entries are [000]-[020].
NOTE: If Section [401] Option 1 and Section [406] are enabled,
either one will work depending on how the installer calls the
premises.
[490] - LINKS DLS Phone Number Preamble
Refer to Section [390]
[499] - Initiate PC-LINK Communications
The installer may initiate a PC-LINK DLS session between a com-
puter and panel by entering this section in the following
manner:
[499] - [Installer’s Code] [499]
The installer should already have the PC-LINK Cable properly
connected between the panel’s header and the downloading
computer as well as have the DLS file waiting for the panel to
connect before entering this command.
5.8 Programmable Output Programming
[501]-[515] - Programmable Output Attributes
PGM output attributes and output type must be programmed
for each PGM output. PGM output options [09] “System Trou-
ble” and [10] “Latched System Event” have a unique set of
attributes listed below the description of each output type.
PGM attributes return to their default settings when PGM output
options are changed . See the programming worksheets for a list
of the default settings for each PGM output type.
CAUTION: Select the normal and active states of each PGM
output to ensure that undesirable output states do not occur
after a loss and restore of AC power.
If you program more than one PGM output as the same output
type (e.g. If PGM 1 and PGM 2 are both programmed as [19]
Command Output 1), the settings for output attributes [1], [2]
and [5] must be the same. This does not apply to outputs pro-
grammed as types [09] and [10].
NOTE: Attribute [3] must be ON for PGM output option [16].
Assigning Partitions to Programmable Outputs
By default, all programmable outputs are assigned to partition 1.
For programmable outputs to work on other partitions, enable
or disable the appropriate partitions in the Partition Assignment
programming sections.
PGM Output Partition Assignment. . . . . . Sections [551] - [564]
PGM Output timer . . . . . . . . . . . . . . . . . . . . . . . Section [170]
[401] - FIRST DOWNLOADING OPTION CODES
Option Downloading Code On/Off Description
1 Downloading Answer ON Downloading Answer Enabled. The system will answer calls for downloading if a suc-
cessful Double call routine is detected. Have the downloading computer call the system
and let the telephone line ring once or twice. After 1 or 2 rings, hang up. If called back
within the programmed Double Call Time (000-255 seconds), the panel will answer on
the first ring.
OFF Downloading Answer Disabled. The system will not answer incoming calls using the
Double Call routine unless the User enables the DLS window. This option can be enabled
by turning Option 2 ON.
2 DLS Window ON User Can Enable DLS Window. The user can use the [*][6][Master Code][5] Command
to enable a 6 hour window in which the panel will answer calls for downloading if a suc-
cessful Double Call routine is detected. If this option is enabled, the window is open upon
power up. The window is on for the full 6 hours if enabled.
OFF User Can Not Enable DLS Window. The user can not enable a window for DLS calls.
NOTE: Options 1 and 2 are not related. One does not need to be enabled for the other to
perform its function.
3 Call-Back ON Call-Back Enabled. When the system answers the downloading computer’s call, both the
computer and the panel will hang up. The panel will then call the Downloading Telephone
Number and connect with the computer at that number. If more than one downloading
computer is to be used, this function should be disabled.
OFF Call-Back Disabled. The downloading computer will have immediate access to the panel
once it is identified as a valid system.
4 User Call-Up ON User Call-Up Enabled. When this feature is enabled, the user may initiate a single call of
the Downloading Telephone by entering [*][6][Master Code][6].
OFF User Call-Up Disabled. An error tone will be generated when [*][6][Master Code][6] is
entered.
5-8 For Future Use