37
[320]-[349] REPORTING CODES
Option Report Code Description
[320]-[327] ZONE ALARMS & ALARM RESTORE
[320]-[327] Zone Alarms & Alarm
Restores
These reporting codes are used by the communicator to transmit zone alarms and restores for zones
1 to 64. These codes are sent to the Alarm & Restore call direction group of the Partition.
[328] MISCELLANEOUS ALARM REPORTING CODES
1 Duress Alarm This reporting code will be transmitted to the monitoring station whenever a Duress code is used to
perform any function on the system. The code is sent to the Alarm & Restore call direction group of
the Partition.
2 Opening After Alarm This reporting code will be transmitted to the monitoring station on Opening if an alarm has
occurred during the previous armed period.The code is sent to the Alarm & Restore call direction
group of the Partition.
3 Recent Closing A Recent Closing transmission shall be sent if an alarm occurs within 2 minutes of an exit time expi-
ration. The Recent Closing report will be sent for the first alarm only. This code is sent to the Alarm &
Restore call direction group of the Partition.
4, 5 Zone Expander Supervi-
sory Alarm & Restore
If the system loses communications with a Zone Expander Module (PC5132, Keypad with on-board
zone), this reporting code will be sent to the Alarm Call Direction group of the System. This is inde-
pendent of the General System Supervisory code sent to the Maintenance Call Direction group.
6 Cross Zone / Police Code
Alarm
When using Cross Zoning (Section 018, Option 6 ON), this reporting code will be sent when two
‘crossed’ zones go into alarm during the Cross Zone period.
When using Police Code (Section 018, Option 6 OFF), this reporting code will be sent when any two
zones go into alarm.
The Double Hit option allows the Cross Zone Police Code reporting code to be sent when two zone
alarms occur on the same zone. The Burglary Verified timer also applies to the Double Hit option.
Only zones programmed as Interior, Interior Delay, Interior Stay/Away, or Delay Stay/Away are
included in the Double Hit option. See Section [176], Burglary Verified Timer and Section [017] Opt
4, Double Hit.
NOTE: Only one reporting code will be sent during each armed to armed period when using Police
Code.
7 Burglary Not Verified When using Cross Zoning (Section 018, Option 6 ON), this reporting code will be sent if the Cross
Zone timer is initiated by the first cross zone alarm, but is not verified by a second before the timer
expires. Valid entries for the Burglary Verified timer are 000-255 minutes (000 to disable).
8 Alarm Canceled If an alarm event is sent after transmission delay has expired, then a cancel window time will start. If
a valid access code is entered during this window, then the Alarm Canceled event is logged and
sent. When this reporting code/event has been acknowledged by the central station a keypad ring-
back will occur.
[329] PRIORITY ALARM AND RESTORE
1,2,3,5,6,7 [F], [A], [P] Alarms &
Restores
These reporting codes will be sent if the keys are used to generate manual alarms. These codes are
sent to the Alarm & Restore call direction group.
4, 8 Auxiliary Input Alarm /
Restore
If a PGM 2 Input is used, these reporting codes will be sent for the alarm and restore on that input.
[330] - [337] ZONE TAMPERS & TAMPER RESTORES
[330] - [337] Zone Tampers & Tamper
Restores
These reporting codes are used by the communicator to transmit zone tampers and restores for
zones 1 to 64. These codes are sent to the system Tamper Alarm & Tamper Restore call direction
group of the System.
[338] MISCELLANEOUS TAMPER REPORTING CODES
1, 2 General System Tamper &
Restore
This reporting code is sent whenever an enrolled module with Tamper inputs is placed in the Tamper
alarm state. These codes are sent to the system Tamper Alarm & Tamper Restore call direction group.
3 Keypad Lockout (See Sec-
tion 5.0)
This reporting code is sent whenever the System enters Keypad Lockout. This code is sent to the sys-
tem Tamper Alarm & Tamper Restore call direction group of the System.
[339] - [341] CLOSING (ARMING) REPORTING CODES
Closing by Users 1-32, 40,
41, 42
A closing by any of these access codes will result in transmission of the corresponding reporting
code.These codes are sent to the Opening and Closing call direction group of the System. “Armed in
Stay Mode” or “Armed in Away Mode” will be logged for this closing type.
[344] 1, 2 Closing by Users 33 & 34
(Duress)
A closing by these access codes will result in transmission of the corresponding reporting code.These
codes are sent to the Opening and Closing call direction group of the System.
See also Duress Alarm Reporting Code.
6 Partial Closing This reporting code will be transmitted to the Central Station with the Closing code if there were
zones manually bypassed at the time of arming to warn of a security compromise. Automatic
bypasses caused by Stay Arming will not cause this code to be transmitted. Zones force armed by
Automatic Arming will transmit in the manner described above. If SIA is used, each zone will be
identified using the UB-XX (Untyped Bypass) identifier. The identified zones will follow the partial
closing code and precede the closing transmission.