38
7 Special Closing If the system is closed (armed) using any of the following methods, this reporting code will be trans-
mitted. “Armed in Stay Mode” or “Armed in Away Mode” will be logged for all closing types.
• Maintenance Code,
• Keyswitch Zone
• Downloading
• Quick Arm (*0)
• Auto Arming.
8 Late to Close If Section 017, Option 5 is ON, when an Auto Arm pre-alert expires, this reporting code will be sent.
Exit Fault If an Exit Fault Pre-alert occurs and Entry delay expires before the system is disarmed, this reporting
code will be sent.
[342] - [344] CLOSING (ARMING) REPORTING CODES
Opening by Users 1-32,
40, 41, 42
An opening by any of these access codes will result in transmission of the corresponding reporting
code. These codes are sent to the Opening and Closing call direction group
[344] Opening by Users 33 &
34 (Duress)
An opening by these access codes will result in transmission of the corresponding reporting code.
These codes are sent to the Opening and Closing call direction group of the System. See also Duress
Alarm Reporting Code.
[344] Auto Arm Cancel/Post-
pone
This reporting code is transmitted when the Auto Arming sequence is canceled or postponed. Can-
cellation or postponement of the sequence can be achieved by entering an access code or by press-
ing the ‘Disarm’ Key on an identified WLSKey during the Auto-Arm-Pre-Alert.
[344] Special Opening If the system is opened (disarmed) using any of the following methods, this reporting code will be
transmitted.
• Maintenance Code
• Keyswitch Zone (WLSKey)
• Downloading.
[345] - [346] MAINTENANCE ALARM AND RESTORAL REPORTING CODES
1 Battery Trouble & Restore The panel will transmit a Battery Trouble Alarm Reporting Code when the backup battery drops
below 11.5 V
DC. The Battery Trouble Restoral Reporting Code will not be transmitted until the bat-
tery has been charged over 12.5 V
DC. These codes are sent to the System Maintenance Call Direction
Group.
2 AC Failure & Restore If the AC supply has failed or has been restored, these reporting codes will be sent. There is a pro-
grammable delay (001-255 minutes) which applies to the trouble and the restore. These reporting
codes are sent to the System Maintenance Call Direction Group.
3 Bell Circuit Trouble &
Restore
If the Bell circuit has been opened or the bell is disconnected, this trouble will be reported. The Bell
Circuit Trouble Restoral Reporting Code will be transmitted as soon as the problem is corrected
These codes are sent to the System Maintenance Call Direction Group.
4 Fire Trouble & Restore An open circuit on any Fire Zone will cause this trouble to be reported. The Fire Trouble Restoral
Reporting Code will be transmitted as soon as the problem is corrected. These codes are sent to the
System Maintenance Call Direction Group (see section 5.3 Basic Programming on page 20).
5 Auxiliary Power Supply
Trouble & Restore
If an auxiliary voltage supply trouble occurs (the Aux PTC has caused the Auxiliary Supply to stop
outputting power to the Keybus), this trouble is reported. These codes are sent to the System Main-
tenance Call Direction Group.
NOTE: If the Electronic Fuse opens due to a short circuit or high current draw, the panel will not
power up when the short is removed if there is still a load applied. The panel must be powered
down and then powered up to restore this condition.
6 TLM Trouble & Restore The TLM Trouble code is sent via the LINKS1000 Cellular Transmitter if enabled and programmed.
The TLM Restore code is sent when the telephone line is restored from the trouble condition. These
reporting codes are sent to the System Maintenance Call Direction Group.
NOTE: The panel will only transmit the signal after the time programmed for the TLM Trouble Delay.
7 General System Trouble
& Restore
These reporting codes are transmitted to report miscellaneous system troubles not reported individu-
ally. Possible causes of this report are as follows:
• PC520X - AC Trouble / Restore
• PC520X - Battery Trouble / Restore
• PC5204 - Supervised Output Circuit Trouble / Restore
• PC520X - Aux Circuit Trouble / Restore
These reporting codes are sent to the System Maintenance Call Direction Group.
NOTE: ‘PC5400 On/Offline and Home Automation Trouble/Restore events’ generate the General
System Trouble, but do not communicate this reporting code.
NOTE: The General System Trouble Restoral Reporting Code will be transmitted when all of the
listed problems are corrected.
8 General System Supervi-
sory & Restore
These reporting codes are transmitted to indicate that the system has lost communications to an
enrolled module or a Keybus Fault has been detected. The first alarm and last restore will initiate the
communications. These codes are sent to the System Maintenance Call Direction Group.
NOTE: If a PC5132 has a supervisory trouble, the panel will signal a Zone Expander Supervisory
alarm, even if only Wireless Keys are enrolled on the module.
[320]-[349] REPORTING CODES
Option Report Code Description