Programming Sections: 5.3 Basic Programming
25
[012] - Keypad Lockout Options
The panel can be programmed to ‘lockout’ keypads if a series of
incorrect access code entries are made. After the Number of
Invalid Codes Before Lockout has been reached the panel will
lock out the keypad for the Lockout Duration and log the
event to the event buffer. For the duration of the lockout the
panel will sound an error tone when any key is pressed.To pro-
gram ‘Number of Invalid Codes Before Lockout’
Enter a number from 000 to 255 to determine the number of
invalid master, duress, user or installer access code entries to
reach keypad lockout. When keypad lockout occurs, the system
is rendered inoperative via keypad for the programmed duration.
When any keys are pressed, an error tone will sound.
To program ‘Lockout Duration’, enter a time from 000 to 255
minutes to determine the length of time before lockout resets
and the keypad can once again be used.
NOTE: If lockout is not reached within the hour roll-over, the
number of invalid attempts is reset to 0.
NOTE: FAP keys are still active during Keypad Lockout.
NOTE: Keypad Lockout is a Global Feature.
To disable Keypad Lockout enter the Number of Invalid Codes
Before Lockout as (000).
NOTE: If Keypad Lockout is active, the panel cannot be armed or
disarmed with a keyswitch.