2
Fire Trouble
Telephone Line Trouble
Low Battery Condition
Bell Output Trouble
Loss of Internal Clock
AUX Power Supply Fault
Tamper by Zone
Failure to Communicate
Module Fault (Supervisory or Tamper)
Camera Troubles via DLM-4L
False Alarm Prevention Features
Audible Exit Delay
Audible Exit Fault
Urgency on Entry Delay
Quick Exit
Swinger Shutdown
Recent Closing Transmission
Cross Zone Alarm
Burglary-verified timer
Double Hit Timer
Communication Delay
Rotating Keypress Buffer
Additional Features
Automatic arming by partition at a specified time, each day of
the week
Keypad activated alarm output and communicator test
Keypad lockout
Audio capability using the PC5936 Audio Interface Module,
allows local intercom and central station 2-way listen-in
All modules connect to the system via a four wire Keybus, up
to 1000’/305m from the main panel
Event buffer can be printed using PC5400 RS-232 Serial Inter-
face module
Supports the Escort5580 Voice Prompt Module, with automa-
tion, lighting, and thermostat control
256 event buffer, time and date stamped
Uploading/downloading capability
Daylight savings time option
Downlook support (DLM-4L v1.0 and PC5108L)
1.4 Additional Devices
In addition to the information below, see the back cover for a
DSC Module Compatibility table.
Keypads
A maximum of 8 keypads can be connected to the control panel.
You can connect any combination of the following listed.
PC5508Z: 8 zone LED keypad, with one zone input
PC5532Z: 32 zone LED keypad, with one zone input
PC5516Z: 16 zone LED keypad, with one zone input
LCD5500Z: programmable messageLCD keypad, with one
zone input
LCD5501Z: fixed message LCD keypad, with one zone input
LCD5501Z32-900 fixed message LCD keypad with integrated
PC5132 wireless receiver
Different keypads (with function keys) can be used for different
size systems: 8 zone, 16 zone, 32 zone, and 64 zone.
NOTE: Please see the PC5020 Module Compatibility Chart on the
back cover for compatible versions.
PC5100 2-Wire Addressable Device Interface Module
The PC5100 module is used to connect 2-wire addressable
devices to the system. Up to 32 2-wire addressable devices can
be added to the system
NOTE: PC5100 v1.0 and lower modules can only support the first
32 zones on the Power864 system.
PC5108 Eight Zone Expander Module
Eight zone expander module can be used to increase the number
of zones on the system. Up to 7 modules can be connected to
increase the system zones to a maximum of 64. (See the PC5108
Installation Instructions Sheet.)
NOTE: PC5108 v1.0 and lower modules can only support the first
32 zones on the Power864 system. PC5108 v1.0 and lower mod-
ules enroll as two modules and use up two supervisory slots.
NOTE: Do not mix PC5108 v1.x and lower modules with PC5108
v2.0 and higher modules on the same system.
PC5132 Wireless Receiver Module
The PC5132 Wireless Receiver module can be used to connect
up to 32 fully supervised wireless devices. (See the PC5132
Installation Manual for details.)
NOTE: Only the first 32 zones on the Power864 system can be
used as wireless zones.
PC5200 Power Supply Module
The PC5200 can provide up to 1 Amp of additional power for
modules or devices connected to the control panel. Up to 4
modules can be connected to the system. Each module requires
a 16.5 volt AC 40 VA transformer and 4 AH battery. (See PC5200
Installation Instructions for details.)
PC5204 Power Supply Output Module
The PC5204 can provide up to 1 Amp of additional power for
modules or devices connected to the control panel. The module
requires a 16.5 volt AC 40 VA transformer and 4 AH battery. In
addition, the module provides 4 programmable high current
voltage outputs. (See PC5204 Installation Instructions for
details.)
PC5208 Eight Low Current Output Module
Adds eight programmable low current outputs (50 mA) to the
control panel. (See the PC5208 Installation Instructions for
details.)
NOTE: If you use the main panel and the PC5208 outputs, PGM 3
will work the same as the first PC5208 output, and PGM 4 will
work the same as the second PC5208 output.
Escort5580 Module
This Escort5580 module will turn any touch-tone telephone into
a fully functional keypad. The module also includes a built-in
interface to control up to 32 power-line carrier devices for auto-
mation control and 4 thermostats for temperature control (See
the Escort5580 Installation Manual for details.)
NOTE: Please see the PC5020 Module Compatibility Chart on the
back cover for compatible versions.
PC5936 Audio Interface Module
The PC5936 Audio Interface modules provide paging, intercom,
room monitor and door answer to the PC5020 control panel.
The modules have built-in two-way voice capability for central
station audio alarm verification (See the PC5936 Installation
Manuals for details).
Three additional devices are available:
PC5921 Intercom Audio Station can be used in conjunction
with the PC5936 Audio Interface Module.

Table of Contents

Other manuals for DSC PC5020

Related product manuals