44
[378] - Test Transmission Time of Day
Program the time of the test transmission in this section. Enter a
4-digit time using the 24 hour clock format (HH:MM). Valid
entries are from 00 to 23 for the hours (HH) and 00 to 59 for the
minutes (MM).
To disable the test transmission, enter [9999] in this section.
Delinquency Transmission Delay The value in this section determines the period of time that the Delinquency Event will be postponed
until it is logged to the Event Buffer and transmitted. Whether this value is in hours or days is deter-
mined if Delinquency is for Activity (hours) or Closing (days) as specified in Section [380] Option 8.
The timer start under the following conditions:
• When the system is armed in the Stay mode
• When the system is disarmed
• When a zone is violated and restored while the system is disarmed/Stay armed (Interior, Interior
Delay, Interior Stay/Away, or Delay Stay/Away zones only).
The activity delinquency timer will be ignored when the system is armed in the Away mode. Zones
that are bypassed in the [*][1] Bypass menu will not reset the timer.
If the system is programmed to monitor Closing Delinquency, the timer will be programmed in
days. The timer will restart every time the system is disarmed.
Activity/Closing DelinquencySection [380], option [8
Communications Cancel Window After TX Delay expires and a zone alarm has been transmitted, the Cancel window will begin. If an
access code is entered during this window, a Communications Cancel reporting code will be com-
municated. If the window expires without an access code entered or a code is entered after the win-
dow, no Opening After Alarm log or communication will occur.
[377] - COMMUNICATION VARIABLES