36
This account code can be up to six digits in length for the SIA
Communications format.
Only SIA supports six digit account codes. If the last two digits of
the account code are FF, the panel will only use the first four dig-
its. All other formats will use the first four digits of the account
code.
The call directions that use this Account Code are System Main-
tenance (Troubles, Zone Faults, etc.) and System Test
Transmissions.
NOTE: SIA will use this account code for all Partitions and System
Events! System events will be identified by Nri0, with Partitions 1-8
using Nri1-8.
[311]-[317] - Partition 1-8 Account Codes
These Account Codes are used by the panel when communicat-
ing events for Partitions 1-8 when using formats other than SIA.
NOTE: All Partition Account Codes are 4 digits in length. Valid
entries are 0000-FFFE.
[320] - [349] REPORTING CODES
Communicator - Reporting Codes
Unless you are using Automatic Contact ID or Automatic SIA for-
mats, reporting codes must be programmed in order for the
panel to report events to the central station.
Reporting codes are two digits and can use hexadecimal digits A
through F. To disable a reporting code, program it as “FF”
(default setting) or “00”. For a complete description of reporting
codes which can be programmed and lists of automatic Contact
ID and SIA format codes, see section Appendix A:
“Reporting
Codes
on page 55.