Section Option Description
316 [002] -- Partition 6 Call Direction - Tamper/Restore
316 [003] -- Partition 6 Call Direction - Opening/Closing
317 [001] -- Partition 7 Call Direction - Alarm/Restore
317 [002] -- Partition 7 Call Direction - Tamper/Restore
317 [003] -- Partition 7 Call Direction - Opening/Closing
318 [001] -- Partition 8 Call Direction - Alarm/Restore
318 [002] -- Partition 8 Call Direction - Tamper/Restore
318 [003] -- Partition 8 Call Direction - Opening/Closing
350 [001] -- Receiver 1 communicator format
350 [002] -- Receiver 2 communicator format
384 2 Communicator backup options
Notifications
The following panel settings may alter the behavior of customer notifications:
Section Option Description
015 4
If this option is ON, keyfob arming notifications will not be associated with a specific
user
Panel Settings Changed Automatically
Some panel settings are changed automatically when the HSPA/CDMA module is connected to the control
panel. These settings should not be altered. They are:
Section Option Value Description
015 6 OFF
Master code is not changeable and must be
OFF to ensure the module communicates the
correct master code
017 6 OFF
Daylights saving time must be disabled to
ensure panel time is accurate
019 6
Set according to
dealer's Alarm.com
setting
Enables Duress Code changes from
Alarm.com
024 5 OFF
Realtime clock must be disabled to ensure
panel time is accurate
041 - 00 User Access Codes must be 6-digits
377
Swinger Shutdown
(Maintenance)
010
Swinger Shutdown for maintenance signals
must be set to 010 to ensure trouble
notifications can be sent.
377
AC Failure
Communication Delay
Random value between
001 and 030
AC Failure Communication Delay should be
set between 001 and 030 to ensure
notifications for power failures are received
377
Wireless Device Low
Battery Transmission
Delay
001
Wireless Device Low Battery Transmission
Delay should be set to 001 to ensure
notifications for low batteries are received