Chapter 5 Programming Worksheets
33
[013] First System Options
[014] Second System Options
[015] Third System Options
[016] Fourth System Options
Opt Def ON OFF
1
Normally Closed Loops
End-of-Line Resistors
2
Double End-of-Line Resistors
Single End-of-Line Resistors
3
Panel shows all Troubles when armed
Panel shows only Fire Troubles when armed
4
Tampers/Faults do not show as open
Tampers/Faults show as open
5
Auto-Arm Schedule in [*][6] and installers
Auto-arm Schedule in Installer Programming Only
6
Audible Exit Fault Enabled
Audible Exit Fault Disabled
7
Event Buffer Follows Swinger Shutdown
Event Buffer Logs Events past Shutdown
8
Temporal Three Fire Signal Enabled
Standard Pulsed Fire Signal
Opt Def ON OFF
1
Arm /Disarm Bell Squawk Enabled
Arm /Disarm Bell Squawk Disabled
2
Bell Squawk During Auto-Arm
No Bell Squawk During Auto-Arm
3
Bell Squawk On Exit Delay
No Bell Squawk On Exit Delay
4
Bell Squawk On Entry Delay
No Bell Squawk On Entry Delay
5
Bell Squawk On Trouble
No Bell Squawk On Trouble
6
Audible Exit with Urgency
Silent Exit Delay
7
Exit Delay Termination Enabled
Exit Delay Termination Disabled
8
Residential Fire Bell is Continuous
Residential Fire Bell is Cut-off
Opt Def ON OFF
1
Fire Key Enabled
Fire Key Disabled
2
Panic Key Audible (Bell / Beeps)
Panic Key Silent
3
Quick Exit Enabled (ON for SIA CP-01)
Quick Exit Disabled
4
Quick Arming Enabled (No Code Required)
Quick Arming Disabled (Code Required)
5
Code Required for Bypassing
Code Not Required for Bypassing
6
Master Code NOT Changeable
Master Code Changeable
7
TLM Enabled
TLM Disabled
8
TLM Audible (Bell) when Armed
TLM Trouble Beeps when Armed
Opt Def ON OFF
1
AC Trouble Displayed
AC Trouble Not Displayed
2
Trouble Light Flashes if AC Fails
Trouble Light does NOT follow AC Status
3
Blank Keypad when Not Used
Keypad Blanking Disabled
4
Code required to remove Keypad Blanking
No Code Required
5
Keypad Backlighting is Enabled
Keypad Backlighting is Disabled
6
Power Save Mode Enabled
Power Save Mode Disabled
7
Bypass Status Displayed While Armed
Bypass Status Not Displayed While Armed
8
Keypad Tampers Enabled
Keypad Tampers Disabled

Other manuals for DSC PowerSeries PC1616

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries PC1616 and is the answer not in the manual?

DSC PowerSeries PC1616 Specifications

General IconGeneral
Partitions2
KeypadsUp to 8
Zones6 on-board
PGMs2
Power Supply16.5VAC
Battery Backup12VDC, 4Ah

Related product manuals