59
1
3
Programing JOB for DC-645 on Control Panel
PREPRINTED
SAMPLE
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
Enter the total length (in mm) of the document.
Pressthe <SET> keywheninputiscompleted.
Tip
• WhenprogrammingaJOB(INPUTmode),press
the<JOG>keytomovetoNEXTorPrevious
display.
<JOG> key: Go to the next display
<JOG> key: Go to the previous display
Tip
• When programming a JOB (INPUT mode), press
the <STOP> key to quit the JOB program and
return to the regular LCD display.
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
Enter the paper width (in mm) of the document.
Pressthe <SET> keywheninputiscompleted.
How to Program Job on Control Panel
TOTAL LENGTH ?
(
210–650
)
460.0mm
PAPER WIDTH ?
(
210–370
)
297.0mm
SIDE MARK 10.0mm
(
0,3–15
)
10mm
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
Measure the distance (in mm) between the
Right edge of the paper and the vertical portion
of the Side mark. Input the distance of Side
mark by <Number> key.
The value must be between 3 and 15 mm when
REG. Mark is not used enter 0.0 mm.
Example:
1. Press the < 3 > key and <JOG> key.
2. Press the < 8 > key 2 times and <JOG> key.
3. Press the < 7 > key and <JOG> key.
4. Press the < 5 > key 3 times and <JOG> key.
5. Press the < 6 > key 3 times and <JOG> key.
6. Press the <SET> key.
52:DUPLO
12345
Continue Page
•••