4.3 THERMOMETER
4.3.1
HOW TO SET SV, AL1 and ALH
4.3.1.1 Hold button for 3 seconds then,
4.3.1.2
SV
After 4.3.1.1, press button to move cursor left, button to increase,
and button to decrese. SV default value is 120
4.3.1.3 AL1
After 4.3.1.1, then press button once unitl AL1 displayed, AL1 default
value is 120
, If necessary press , and button to set.
4.3.1.4 ALH: After 4.3.1.3, Press button 3 times it will display ALH, default of ALH is
30
4.3.1.5 After ALH, press button 3 times go back to