7.3 Step-motor error messages
Error number Meaning Remedy
Error 400 Error in M4 step-motor amplifier for
the feed clamp
Check motor, step-motor amplifier and
cable; check step-motor amplifier power
supply
Error 401 Error in M3 step-motor amplifier for
the corner-blade block
Check motor, step-motor amplifier and
cable; check step-motor amplifier power
supply
Error 402 Error in step-motor amplifier for the
corner-blade slant at the seam-start
Check motor, step-motor amplifier and
cable; check step-motor amplifier power
supply; check reference switch
Error 403 Error in step-motor amplifier for the
corner-blade slant at the seam-end
Check motor, step-motor amplifier and
cable; check step-motor amplifier power
supply; check reference switch
Error 404 Error in step-motor amplifier for the
tape feeder
Check motor, step-motor amplifier and
cable; check step-motor amplifier power
supply
Error 405 Error in step-motor amplifier for the
incision of slitting pipe
Check motor, step-motor amplifier and
cable; check step-motor amplifier power
supply
* If this error display occurs frequently, please contact our service staff
7.4 CAN-Module error messages
Error number Meaning Remedy
Error 500 Error in the CAN-Modules Check cable
Error 510 Knife block unit (AC201)
Check cable and jumper setting
Error 511 Knife block unit (AC201)
Check power supply
Error 512 Knife block unit (AC201)
Check DIP-switches
Error 520 Transport unit (AC101) Check cable and jumper setting
Error 521 Transport unit (AC101)
Check power supply
Error 522 Transport unit (AC101)
Check DIP-switches
Error 530 Transfer device (AC001) Check cable and jumper setting
Error 531 Transfer device (AC001)
Check power supply
Error 532 Transfer device (AC001)
Check DIP-switches
Error 540 Tape feeder with step-motor
(AC 301)
Check cable and jumper setting
Error 541 Tape feeder with step-motor
(AC 301)
Check power supply
Error 542 Tape feeder with step-motor
(AC 301)
Check DIP-switches
91