Error code Description Remedy
3107 Machine temperature
- Vent holes closed
- Ventilation grid soiled
- Check the vent holes
- Clean the ventilation grid
3109 Safe stop is switched on
Switch off the safe stop
3121 Insufficient or missing compressed air
Increase the flow or stabilize the
compressed air
3123 Oil sensor active
Topupoil
3210 Thread breakage
Re-thread the thread again
3215 Empty bobbin (Residual thread monitoring)
Insert a full bobbin.
3220 Empty bobbin (Residual thread monitoring)
Insert a full bobbin.
3500 Error calculation of the contour data
- Reload contour data
- Check contour data
3501 Aim position of XY-clamp outside the movement
limits
Adjust the contour data
3502 Aim position of XY-clamp within “defended areas”
Adjust the contour data
3721
3722
Internal error
- Switch the machine off and on
again
- Software update
- Inform the DA-Service
Control/Machine
4201 Internal CF-card faulty
- Switch the machine off and on
again
- R et ro fi t /re p la c e th e c on t rol
5301 Program not sewable
- Copy the program to the DAC
6551
-
6554
6651
-
6653
6751
-
6761
Error machine head position/ AD-Converter/
Processor error
Internal error
- Switch the machine off and on
again
- Software update
- Inform the DA-Service
6952 Error stepping motor drive
Internal error
- Switch the machine off and on
again
- Software update
- Inform the DA-Service
Communication
7801 Communication control panel interface
- Line interruption
-Cable
- Switch the machine off and on
again
- Software update
- Inform the DA-Service
8151
8156
-
8159
IDMA error
-Failure
- Faulty control
- Switch the machine off and on
again
- Replace the control
8152
-
8154
IDMA error
- Inter nal error
- Switch the machine off and on
again
- Software update
- Inform the DA-Service
61
1