SECTION 6 – KEYPAD
• The EC 2000 can be either controlled via the keypad or from external pilot device, but initial
programming must be done with the keypad.
• The keypad is plugged into the “PL2-KEYPAD” male pin header on 15-1200-1.
• Dynamatic® part number: 037-000544-0100 (Keypad with 10ft cable)
o Other cable sizes available upon request
Table 4: Keypad Button Descriptions
Allows user into a menu or submenu; confirms value
change
Allows user to back out of a menu or submenu.
User changes displayed meters (Meter 1 or Meter 2) on
bottom two lines of the keypad.
Meter options include: Reference, Motor Amps,
Clutch Amps, Brake Amps, Feedback, and Drive
Speed.
Successive pushing locks or unlocks the keypad
“Locked” does not allow changing of parameters
Allows user to cycle through menus or values in
ascending order
Allows user to change between individual digits
Allows user to cycle through menus or values in
descending order
Reference point for speed or torque control
Switches between speed or torque control
Momentary run function at a preset reference
Switches between “Manual” and “Automatic” mode
“Manual” refers to the use of a potentiometer for
speed/torque reference, while “Automatic” refers
to the use of a follower input such as 0-10V or 4-
20mA .
Switches between “Local” and “Remote” mode
“Local” mode is for operation from the keypad,
while “Remote” mode is for operation from
external pilot devices. Only available to toggle if
enabled in Menu A, Parameter 12.
Will only work in “Local” mode
The control can either be programmed to stop
the control via the keypad or external push
button (See Menu K).