EasyManuals Logo

Dynamatic EC 2000 User Manual

Dynamatic EC 2000
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
33
7.8 Menu H: UNITS
1. PROCESS UNITS
RPM (default)
PERCENT (used for torque mode)
USER
USER can be selected to display speed in something other than RPM. If chosen, Parameters
2-4 are opened for changing. If not, Parameter 1 is the only one that is open.
2. USER UNITS
RPM (revolutions per minute)
RPS (revolutions per second)
RPH (revolutions per hour)
CPM (cycles per minute)
CPS (cycles per second)
CPH (cycles per hour)
FPM (feet per minute)
FPS (feet per second)
FPH (feet per hour)
SPM (strokes per minute)
SPS (strokes per second)
SPH (strokes per hour)
XPM (x per minute)
XPS (x per second)
XPH (x per hour)
3. USER DECIMAL PNT
0 (no decimal)
1 (one decimal)
2 (two decimal)
3 (three decimal)
4. MAX USER VALUE
Enter the number of user units that corresponds with the top process speed. For example, if
the maximum press speed is 40 SPM, the MAX USER VALUE will be 40.0 (USER DECIMAL PNT
will be 1).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dynamatic EC 2000 and is the answer not in the manual?

Dynamatic EC 2000 Specifications

General IconGeneral
BrandDynamatic
ModelEC 2000
CategoryController
LanguageEnglish