7. COIL OPEN FLT EN
If enabled, the control will fault if there is no detected clutch current when the output voltage
is applied.
• ENABLE (default)
• DISABLE
8. SPD FDBK FLT EN
If enabled, the control will fault if there is no detected speed feedback signal (ie AC
Tachometer Generator) when the control is trying to run at a set speed.
• ENABLE (default)
• DISABLE
9. FLT TEST DELAY
The time between the when the fault is sensed and when the fault is indicated. (default: 10
sec).
10. KEYPAD FLT ENABLE
If enabled, the control will fault if the keypad is disconnected.
• ENABLE
• DISABLE (default)
11. OVERSPD FLT EN
If enabled, the control will fault if the speed set by parameter 7: OVERSPEED TRIP is reached.
• ENABLE
• DISABLE (default)
12. OVSPD FLT ACTION
• RUN (keeps running if an overspeed occurs)
• STOP (stops if an overspeed occurs)
13. OVERSPEED TRIP
The overspeed threshold setpoint.