TROUBLESHOOTING
General troubleshooting procedure
If there are any error messages, make sure that:
■ The handbrake is engaged.
■ The ignition is set to ON.
■ The battery has sufficient voltage.
■ The oil level is correct.
■ The jacks do not have damages.
■ The cables do not have damages.
If this does not solve the problem, there could be something wrong with the drive units. When you think
the drive units do not operrate correctly, speak to your E&P Hydraulics dealer/installer.
Error descriptions
Symbol Error message Description Possible solution
Pull parkbrake
The handbrake is not
engaged.
Engage the handbrake.
Vehicle battery
empty
Charge battery
The battery does not
have sufficient power
for the leveling system
to operate.
Charge the battery.
Angle of incline
too large
Use manual op-
eration
The inclination is too
large to automatically
level the vehicle.
Manually level the vehicle. If the jacks are
too short, put blocks below the jacks.
Warning:
■ One ore more wheels
could come off the
ground.
■ The vehicle could
move because of a
slippery surface.
Overheat error
Wait for cool
down
The pump has operat-
ed for too long and is
too hot.
Let the pump cool down before you use the
leveling system.
0001 49
US