Installer Menu Options i-on Range
Page 112
Zone HUA (PA) and restore
Keypad HUA (PA), Keypad HUA (PA) restore
RF HUA (PA), RF HUA (PA) restore
Radio keypad HUA (PA), radio keypad HUA (PA)
restore
Zone HUD fault and restore
Keypad tamper and restore
Detector tamper and restore
Lid tamper and restore
Bell tamper and restore
Radio keypad tamper and restore
External siren tamper and restore
WAM tamper and restore
Technical alarm and restore
Jamming fail and restore*
Zone low battery fail and restore
Zone External Warning Device fault and restore
Control unit battery low/ missing and restore
External battery fault and restore
Smoke/WAM psu fail and restore
Fail and restore for: Aux 12V, Aux 14.4V, Bell 12V,
Bus 12V, System 12V
Ext Siren/WAM low battery fail and restore
Control unit battery low/fail and restore
External PSU low volts via zone n
*Notes:
1. The control unit communicates Jamming, Supervision when the system is unset.
Restorals
When you enable a CID/SIA Report Group, or when you use Fast Format reporting, the
control unit sends the relevant telegram both when an event occurs, and when the
condition causing the event stops. The second transmission of the telegram is also called
a “restore”.
You can enable or disable restoral reporting by selecting Communications – ARC
Reporting – Restorals. The options available are:
Disabled
Restore off. The control unit does not communicate restores.
Enabled.
Restore on. The control unit does communicate restores.