i-on Range Installer Menu Options
Page 129
System Voltage
This option displays the dc voltage present on the expander
PCB just after the mains transformer and principal voltage
regulator. If it shows anything other than 13.6V then this
indicates that there may be either a mains “brown out” or that
the expander is running on its standby battery.
Aux 1 Voltage
This option shows the voltage on the 12V line of the Aux 1
terminals.
Aux 2 Voltage
This option shows the voltage on the 12V line of the Aux 2
terminals.
Comms O/P voltage
This option shows the voltage on the 12V positive terminal of
the plug-by communications connector.
Bus Voltage
This option shows the voltage on the 12V line of the system bus
going out of the expander.
Load Current
This shows the total current drawn by Aux 1, Aux 2, Comms
O/P 12V supply, and the bus out 12V supply.
Mains Condition
This option shows the condition of the mains power at the
expander. It shows “Healthy” when mains is present or “Missing”
when mains is absent.
Battery 1 Status
This option shows the condition of battery 1. “Health” means
battery present, in good condition and charged. “Low” mean
battery present but discharged. “Missing” means battery is not
connected.
Battery 2 Status
160
This option will be present if you have an EXP-PSU connected
to the system and have enabled its battery 2 in
Detectors/Devices Wired Expanders - Edit Expanders (see
page 55). The option shows “Healthy”, “Low” and “Missing” with
the same meanings as in Battery 1 Status.
Walk test
The walk test menu provides several different ways of organising a walk test. The options
within Walk Test are:
Chime
Use this option to turn a chime tone on or off. When the chime
tone is on, the keypads and loudspeakers will sound a chime
tone for each zone that triggers while you are performing a walk
test.
System
This option allows you to walk round the entire system and test
all the zones.
Partitions
30 40 50 160
Use this option to select one or more partitions, and test the
zones only within those partitions.
Use or to scroll up and down the list of partitions. Press
or to display “Yes” at the end of the bottom line to mark the
partition as one you want to test.
Expanders
30 50 160
Use this option to select an individual expander, and test the
zones belonging to just that expander.