Appendix VII: Log Messages
This Appendix gives short explanations of the messages that may be stored in the control
unit’s log.
Please note that many of the messages refer to specific equipment items by the bus and
device number. Therefore, it is not possible to show in this list the exact log message that
you may be seeing on any given installation.
The list itself is sorted alphabetically by the text of the message. In the column “Event Log
Text” you will see “==” or sometimes “#”. These characters stand in for the zone, user or
device number that the control unit has recorded for the event being logged. In the
“Description” column this is shown as “nn” or “n”. In the first seven messages listed the
characters “$m” stand in for the type of communications module fitted.
Log Events
Communicator failed to send
alarm.
Communications line failed.
Communications line restored.
SMS call failed to get to
destination.
Speech dialler failed to send
alarm.
24 hour alarm on zone n restored.
AC mains failed and was
communicated.
A zone assigned to partition 1 with
type "AC Fail" was triggered.
A zone assigned to partition 1 with
type "AC Fail" was restored.
Alarm has been confirmed by a
missing external prox reader on
keypad nn.
An alarm was confirmed by a user
on the web browser interface
typing the password incorrectly
more than four times in a row,
Confirmed alarm with tamper on
keypad.
Confirmed alarm with tamper on
expander.
Confirmed alarm with tamper on
AUX tamper terminals
Confirmed alarm with tamper on
bell.
Confirmed alarm with tamper on
radio keypad.
Periodic alarm test call made.
Manual alarm test call made.
All communications paths have a
fault.
All communications path faults
restored.
An alarm was confirmed by a bus
tamper.
Alarm confirmed by panel
jamming.
Confirmed alarm with tamper on
control unit lid.
Confirmed alarm with tamper on
radio siren n.
Confirmed alarm with tamper on
WAM n.
User nn defered calendar setting
on partition n.
All lines to alarm transmission
equipment failed.
Line to alarm transmission
equipment restored.
Alarm transmission equipment has
a single line fault.
The system was part set by
calendar setting.
Partition n was part set by
calendar setting.
Partition n set by calendar setting.
Partition n unset by calendar
setting.
The system was full set by
calendar setting.
The system was unset by calendar
setting.
User defered calendar setting of
system.
Calendar setting of system failed.
Calendar setting of partition failed.
Aux Tamper terminals on main
pcb open circuit (i-on160 only)
Aus Tamper terminals on main
pcb closed circuit (i-on160 only)
Control unit 14.4V supply failed
(EUR versions only)
Control unit 14.4V supply restored
(EUR versions only)
Control unit 12V Aux DC not
working.
Control unit 12V Aux DC restored.
There is an error on loading the
control unit with its software.
Control unit battery restored.
Control unit battery failed load test.
Control unit battery missing or low.
Control unit battery restored.
Control unit battery charger failed.