The Installer Menu i-on Range
Page 40
MENU Option
Factory Default
Notes
comply with EN50131.
Appears in EUR versions, OR only
when System Options
Confirmation Mode is “Basic”.
Panel Loudspeaker
Loudspeaker 1 (or 2)
(Two loudspeakers on i-on160EX.)
Volume
****
Partitions
01...04 (i-on30)
01...04 (i-on40)
01...05 (i-on50)
01...20 (i-on160)
Yes
30 40 50 160 Appears
only in a Partitioned system.
Assigned to all partitions. Number
of partitions depends on panel
type.
Entry Alarm Delay
Enabled
This setting is required in order to
comply with EN50131 8.3.8.2.
Abort Time
120 seconds
Supervision
Tamper
Jamming
Tamper
Force Set
Off
Tamper Omit
Disabled
This setting is required in order to
comply with EN50131.
CSID Code
0000
Silence Alerts
User Code
Mains Fail Delay
0 minutes
This setting is required in order to
comply with EN50131.
Battery 2
Disabled
160. This value depends
on how you answer the Battery 2
monitoring question during the
initial start-up.
Set Date & Time
Panel Tamper Return
CC
5 COMMUNICATIONS
ARC Reporting
Only visible on i-on30EXD and i-
on50EXD or when suitable
communications module fitted.
To comply with EN50131 the panel
must have a communicator.
Call Mode
Single
A “single” or “alternate” setting is
required in order to comply with
EN50131.
Phone book
Empty
IP Network
Only visible when suitable
communications module fitted.
Account Number
000000
Part setting system has one
account number. A partitioned
system has one account number
per partition.
Report Type
Fast Format
Fast Format channels
UK
Channel 1: Fire Alarm
Channel 2: Hold Up Alarm
Channel 3: Burglar Alarm
Channel 4: Open / Close
Channel 5: Zone Omit (System) (see Note 1)
Channel 6: Tamper
Channel 7: Confirmed Alarm
Channel 8: General Fault
Appears only when Report
Type=Fast Format
1. In EUR versions Channel 5 is
Zone Omit (Setting) by default.
CID/SIA Events
Fire Alarm: Yes
Hold Up Alarm: Yes
Burglar Alarm: Yes
Notes:
1. Appears when Report Type=CID
or SIA.