i-on Range
Page 33
Installer Menu
Important: Where noted below the defaults listed enable the control unit to comply with
EN50131 requirements. If you change those settings then the installation may no longer
comply. If the control unit does not comply with EN50131 you must remove any labelling
that indicates compliance.
30 50 160
First radio expander with spare
zones
Appears only if a radio expander is
available on the bus.
Zone number depends on
expander number.
Deletes all radio zones on the
selected expander.
Zone 000...159
(see note)
Actual number of zones depends
on panel type and expanders
fitted.
30 40 50 160
Appears only in a Partitioned
system and when zones have a
type other than “Not Used”.
Chime: No
Soak Test: No
Double Knock: No (not i-on16)
Part Set B: No
Part Set C: No (level setting system only)
Part Set D: No (level setting system only)
Part Set: No (partition system only, not on i-
on16)
Omittable: No
Force Set Omit: No
Masking: No (not i-on16)
Inverted: No (not i-on16)
Shock No
Roller Shutter: No (see notes)
Reset: No
Appears when zone is given a type
other than “Not Used”.
Some attributes are only available
on particular zone types.
Double Knock does not comply
with EN51031.
Masking must be enabled in
System Options.
(Roller Shutter is available only on
i-on160EXEUR.)
Display shows expanders currently
addressed on bus. Max number
depends on control unit type.
nn is between 01 and 45,
depending on control unit type.
Appears only in a partitioned
system.
Zero when expander first added to bus.
(Alarm and tamper tones always
be emitted at 100%.)