The Installer Menu i-on Range
Page 36
MENU Option
Factory Default
Notes
partitions.
Wired outputs
Panel
Name
Type
Polarity
Output 01
Siren
Normal
Output 02
Strobe
Normal
Output 03
Siren
Normal
Output 04
Strobe
Normal
16 40
i-on16/i-on40 do not have separate
Siren and Strobe outputs.
Panel
Name
Type
Polarity
Siren
Siren
Normal
Strobe
Strobe
Normal
PAN>OP1
Siren
Normal
PAN>OP2
Strobe
Normal
PAN>OP3
Siren
Normal
PAN>OP4
Strobe
Normal
30 50 160
In addition to Siren and Strobe:
i-on30EX has one output
i-on50EX has three outputs
i-on160EX has four outputs.
NOTE: You cannot change Siren
and Strobe outputs to other types.
Pulsed
No
Partitions
All outputs allocated to all partitions.
Appears only in a Partitioned
system.
Delay
0 seconds
Appears when Pulsed set to “Yes”.
On time
1 second
Appears when Pulsed set to “Yes”.
Exp. W1-nn
Name
Type
Polarity
W1>nn>01
Not Used
Normal
W1>nn>02
Not Used
Normal
W1>nn>03
Not Used
Normal
W1>nn>04
Not Used
Normal
30 50 160
Appears only if EXP-W1 or EXP-
PSU added to bus.
“nn” = bus address
Pulsed
No
Partitions
All outputs allocated to all partitions.
Appears only in a Partitioned
system.
Delay
0 seconds
Appears when Pulsed set to “Yes”.
On time
1 second
Appears when Pulsed set to “Yes”.
Keypad 1-nn
Name
Type
Polarity
K1>nn>01
Not Used
Normal
Appears only when a suitable
keypad is fitted.
“nn” = keypad number
Pulsed
No
Partitions
All outputs allocated to all partitions.
Appears only in a Partitioned
system.
Delay
0 seconds
Appears when Pulsed set to “Yes”.
On time
1 second
Appears when Pulsed set to “Yes”.
Plug-by outputs
30 40 50 160
Name
Type
Polarity
Output 01
Fire
Normal
Output 02
Hold Up Alarm
Normal
Output 03
Burglar Alarm
Normal
Output 04
Open / Close
Inverted
Output 05
Zone Omit (System)
(see Note)
Normal
Output 06
Tamper
Normal
Output 07
Confirmed Alarm
Normal
Output 08
General Fault
Normal
Output 09
AC Fail
Normal
Output 10
Battery Fault
Normal
Output 11
Technical Alarm
Normal
Output 12
Alarm Abort
Normal
Output 13
Ext PSU Low Volt
Normal
Output 14
Ext PSU Fault
Normal
Output 15
24 Hour Alarm
Normal
Output 16
RF Fault
Normal
i-on30 = Output 01...12
i-on40 = Output 01...12
i-on50 = Output 01...16
i-on160 = Output 01...16
Note: on EUR systems the default
for plug-by output 5 is Zone Omit
(Setting)
Pulsed
No
Partitions
All outputs allocated to all partitions.
Appears only in a Partitioned
system.
Delay
0 seconds
Appears when Pulsed set to “Yes”.