i-on Range Appendix II
Page 143
If either User 02 or 03 opens the Front Door this starts the entry time and tone. The user
enters their code or presents a Prox tag to the keypad in their department. The system
then unsets their partition and the common area.
If the Master user opens the Front Door and enters their code or presents a Prox to a
keypad then only P1, the common area, will unset. The keypad then gives the master user
the option to unset either Factory or Office or both. This allows the manager to open only
the area they want to enter, leaving the other area protected.