The System Bus i-on Range
Page 28
Figure
7.
Zone Numbering Example.
In table form, the zone numbering for the example in Figure 3 would look like this:
Control Unit
EXPW-10 (device 1-01)
EXPR10 (device 1-02)
Zone No.
Address
Used
Zone
Address
Used
Zone
Address
Used
Zone 000
PAN<Z00
*
Zone 010
W0<01<00
*
Zone 020
R0<02<00
*
Zone 001
PAN<Z01
*
Zone 011
W0<01<01
*
Zone 021
R0<02<01
*
Zone 002
PAN<Z02
*
Zone 012
W0<01<02
*
Zone 022
R0<02<02
*
Zone 003
PAN<Z03
*
Zone 013
W0<01<03
*
Zone 023
R0<02<03
*
Zone 004
PAN<Z04
Zone 014
W0<01<04
*
Zone 024
R0<02<04
*
Zone 005
PAN<Z05
Zone 015
W0<01<05
Zone 025
R0<02<05
Zone 006
PAN<Z06
Zone 016
W0<01<06
Zone 026
R0<02<06
Zone 007
PAN<Z07
Zone 017
W0<01<07
Zone 027
R0<02<07
Zone 008
PAN<Z08
Zone 018
W0<01<08
Zone 028
R0<02<08
Zone 009
PAN<Z09
Zone 019
W0<01<09
Zone 029
R0<02<09
The control unit has allocated each expander a block of zone numbers, up to the capacity
of the device. Note the link between zone number and connection point address. The last
digit of the connection point address is the same as the last digit of the zone number. The
middle digits of the connection point address (the bus device number - underlined) are the
same as the first two digits of the zone number (underlined).