The Installer Menu i-on Range
Page 38
MENU Option
Factory Default
Notes
systems. Applies to both full and
part set partition.
Siren Delay
0 minutes
For full set only.
Siren Time
15 minutes
For full set only.
To comply with EN50131-1 Clause
8.6 minimum is 90s, maximum is
15mins.
Strobe on Set
Off
Strobe on Unset
Off
Part Set Exit Mode
Instant Set
Part Set Settle Time
15 seconds
Appears only if Part Set Exit Mode
is “Final Door” , “Lock Set” or “Exit
Terminate”.
Part Set Exit Time
40 seconds
Appears only if Part Set Exit Mode
is “Timed Set” or “Silent Set”.
Part Set Entry Time
40 seconds
Part Set Alarm
Response
Siren
Includes Internal alarm.
This setting is required in order to
comply with EN50131.
Part Set Siren Delay
0 minutes
For part set.
Part Set Siren Time
15 minutes
For part set.
To comply with EN50131-1 Clause
8.6 minimum is 90s, maximum is
15mins.
Part Set Final Exit
Final exit
Part Set Entry Route
Entry Route
Part Set Strobe Set
Off
Part Set Strobe Unset
Off
Partition 2...nn
“Partition nn
Number of partitions depends on
panel type. All other defaults as for
Partition 1.
Full Set Link
Partitions 2-nn: No
30 40 50 160. Number of
partitions depends on panel type.
Partition 1 is common partition.
Calendar Set
None
50 160
No events or partitions
4 SYSTEM OPTIONS
Wired Zone type
Select the global wiring type during
initial power up. Also affects i-on16
when KEY-KPZ01 connected.
Panel Zones
2 Wire FSL 2k2/4k7
30 40 50 160
All Zones
2 Wire FSL 2k2/4k7
30 50 160
This option also appears on i-on16
and i-on40 when a wired keypad
with zones is fitted.
User Access
HUA keys active
No
Quick Set
No
This setting is required in order to
comply with EN50131.
Quick Omit
No
User code reqd
Yes
This setting is required in order to
comply with EN50131.
2 Way Replies
Yes
Used with FOB-2W-4B.
2W Set Instant
Yes
Used with FOB-2W-4B.
Duress Enable
No
(Change to Yes for Duress Code.)
User reset
Zone alarms
Yes
This option appears only if
Confirmation Mode is ”Basic”