Installer Menu Options i-on Range
Page 50
One partition only
Any partition
01
HUA
03
Normal Alarm
02
Fire
05
Final Exit
04
24 Hr
06
Entry Route
07
Technical
08
Key Switch Momentary
10
Tamper
09
Key Switch Latched
11
External PSU AC fail
17
Log Only
12
External PSU Battery fault
18
Exit Terminate
13
External PSU Low Volts
21
Lock Set
14
External PSU Fault
24
Tamper Return
15
External Warning Device
Fault
16
Hold Up Device Fault
Note: If you assign a zone to more than one partition then that zone will only be set when
all the partitions it belongs to are set.
When delivered from the factory, or if you restore the control unit to factory settings, then
all zones default to type Not Used (NU). When you assign a zone to a type other than NU
the control unit initially assigns the zone to partition 1.
Once you have entered the Partitions menu, press or to scroll through the list of
partitions followed by or to assign/de-assign the zone to each partition as necessary.
If you wish to assign/de-assign the zones to many partitions then (for zones types that
allow this) you can use the “All Partitions” option (in between the first and last partitions on
the menu) to either assign or de-assign the zone to all partitions in one go, as follows:
1. Press or to show “All Partitions” on the bottom line of the display.
2. Press or to change the last word on the bottom right of the display to:
“Yes” to assign the zone to every partition.
“No” to de-assign the zone from every partition.
3. Press or to scroll through the partition list and change the assignment of the
zone as necessary.
Note that if you de-assign a zone from every partition and then try to leave the menu by
pressing the control unit will display a warning and return you to the Partitions menu.
Any zone that is in use (has a type other than “NU”) must be assigned to at least one
partition.
Zone Attributes
Note: This menu does not appear if a zone has the type “Not Used”, “HUA”, “Fire”, or
“Keyswitch Momentary”.
You can assign more than one attribute to a zone. Some attributes are not available for
certain zone types. In addition, some attributes may be unavailable for radio zones. The
display shows only the available attributes for the zone type you select.
To enable an attribute for a zone press or until the bottom line of the display shows
“Yes” at the right hand end.