Installer Menu Options i-on Range
Page 68
Type:
(nn=shortcut)
Active when:
Assign to
Partitions?
Pulsed?
If the unconfirmed alarm is caused by the expiry of
the entry timer, then for:
DD243 a further two zones which are not on the
entry route must be triggered to activate the output.
BS8243 one zone not on the entry route must be
triggered to activate the output.
RF Low Battery
(08)
A wirefree detector reports a low battery. The output
remains active until all detectors stop reporting low
batteries.
Yes
Yes
RF Supervision
(09)
There is a supervision failure on any radio zone. The
output remains active until all supervision failures
are reset.
Yes
Yes
RF Jamming (10)
The control unit detects jamming. The output
remains on until all jamming disappears and the
system is reset.
No
Yes
RF Fault (11)
There are any of the following faults: RF Low
Battery, RF supervision, RF jamming and the
system is reset.
Yes
Yes
A/C Fail (12)
Either mains power is absent, OR a zone of type
“External PSU A/C Fail” has been triggered. The
action of this output depends on the value
programmed in System Options Mains Fail Delay
(see page 103).
No
Yes
Battery Fault (13)
The control unit detects a fault with its backup
battery, OR a zone of type “External PSU Battery
Fault” has been triggered. If the alert was caused by
an “External PSU Battery Fault” zone then the
control unit deactivates the output when the zone
has been restored and a user has acknowledges the
fault by entering a valid access code.
If the alert was caused by a fault with the control
unit’s backup battery then the control unit
deactivates the output when it detects a good
battery.
Note: To cause the control unit to check its backup
battery use the Test - Battery(s) - Panel option (see
page 134).
No
Yes
External PSU Low
Volts (14)
30 40 50
160
An external power supply has triggered an External
PSU Low Volts zone.
The control unit deactivates the output when the
zone has been restored and a user has
acknowledges the fault by entering a valid access
code.
No
Yes