7. PROGRAMMABLE PARAMETERS
Parameters available in configuration program are divided into groups: Access,
Transmission, Inputs/Outputs, Monitoring, Restrictions, SMS Notifications, Link
control, RS-232, Phone line and Firmware. Every from these groups will be
described in detail in next part of this manual.
7.1. ACCESS
7.1.1. Parameters
7.1.1.1. Device mode
Depending of user preferences, a device may operate in 1 out 4 modes (available
from scrolled list) :
o GPRS & SMS: GPRS standard transmission (TCP/IP Protocol), and if any
problems follow with this link it automatically SMS mode will follow.
o SMS: Transmission only in SMS mode, without trial to establish GPRS link
o GPRS: GPRS standard transmission (TCP/IP Protocol), and in case of any
problems with this link no transmission will follow.
o Serverless: no transmission to the server with is possible, remote
communication possible only via SMS notifications to the user