7.3.2.3. Additional conditions
If option “Dependent on state transitions from non-active to active of one of the
inputs” is chosen, we might configure additional conditions for output activations:
o Never: input disturbance does not cause operation of sabotage output,
o No network: input disturbance causes actuation of sabotage output if sending
of information to server is impossible.
o Always: every input disturbance causes actuation of sabotage output.
o Available network: input disturbance causes actuation of sabotage output if
sending of information to server is possible.
Note : Both outputs may be controlled by SMS commands.
7.3.3. Advanced outputs control
The user is able to determine an alternative course of action to go over basic
outputs configuration function described in 7.3.2 Outputs. In the “Advanced outputs
control” you may define separately the behavior of each of the outputs, depending
on events taking place. “Advanced outputs control” differs from the existing basic
“Outputs configuration” by:
o it is possible not only to turn on but also to turn off the output
o output can be activated temporarily for specified amount of time
o there is a complete list of events for which you can define the behavior of the
output
Note: where possible, use either the basic configuration of outputs (7.3.2
Outputs) or with an “Advanced outputs control”!
In particular, the basic configuration of existing options: “No GSM signal
(immediately after detection)” and “Dependent on state transitions from non-active