Note:
1) For all protocols you may use following options:
o [Enable SMS sending] which means that in case of no GPRS connection,
data will be sent via SMS (if this mode will be accessible).
o [Don’t transmit data when external phone line is available] which means
that when the external PSTN line is available then it will be used during
transmission from the control panel.
2) [Disable CRC checking] option may be used for ContactID and Ademco formats.
Some control panel generate improper messages regarding a control sum for
transmitted data, the device is not able to confirm collection of data, and as a result
the panel tries to send them again (until execution of all determined trials). Select
this option to avoid the above mentioned.
3) In case of DTMF protocol we gain access to specific parameters used to generate
some control signals.