9 Operating faults Trouble shooting
Fault
Possible cause
Rectification
Metering pump does not
work, green LED not showing
(only E10)
Incorrect voltage
Check power supply
mains power cable damaged
change mains power cable
wrong connection
check connections acc. clamp plan
Pump does not suck up
despite bleeding and max.
stroke setting
deposits, adhesions or drying-out of
the valves
rinse the metering head through the
suction tube, if necessary remove
and clean or replace the valves
Metering head is leaking,
medium is escaping from
leaking connection
Metering head is loose
Tighten metering head screw
diagonally (see chapter 8.2)
Diaphragm ruptured
Replace diaphragm
Metering pump does not
work, although motor is
running
Air in pump head
Vent metering head
Metering volume setting too low Increase stroke volume setting
Metering pump is not running,
and motor is not working
despite of mains connection
Motor turned off by winding
protection
Motor turns on automatically after
cooling
Motor overload caused by too high
back-pressure
Check metering line