11 Technical Specifications
11.1 Pump key
1. Electrical Version
E 00 = Terminal box on motor,
mechanical stroke adjustment
E10 = Electrical motor connection, on/off switch
mechanical stroke adjustment
2. Pump output 50 Hz (60 Hz)
01400 = 140 l/h (168 l/h)
02100 = 210 l/h (252 l/h)
04500 = 450 l/h (540 l/h)
06300 = 630 l/h (756 l/h)
07500 = 750 l/h (900 l/h)
special version: high pressure
01400 vs. 1.2 MPa (12 bar) = 135 l/h (162 l/h)
02100 vs. 1.0 MPa (10 bar) = 202 l/h (242 l/h)
3. Pump head material
PP = PP (Standard)
PV = PVDF
VA = V4A (stainless steel)
VC = PVC
4. Metering backpressure (not freely selectable)
03 = 0.3 MPa (3 bar) (0.25 MPa)
04 = 0.4 MPa (4 bar) (0.33 MPa)
06 = 0.6 MPa (6 bar) (0.5 MPa)
08 = 0.8 MPa (8 bar) (0.6 MPa)
10 = 1 MPa (10 bar) (0.8 MPa)
special version: high pressure:
12 = 1.2 MPa (12 bar) (for 140 l/h) (0,96 MPa)
5. Gasket material
FP = Viton B (Standard)
EP = EPDM
K = Kalrez
6. Ball material
KE = Ceramic (Standard)
VA = V4A stainless steel
PT = Teflon
7. Valve material
PP = PP (Standard)
PV = PVDF
VA = V4A stainless steel
VC = PVC
8. Valve spring
01 = SAV and DRV spring-loaded
10 = SAV without spring, DRV spring-loaded
99 = without spring (Standard)
9. Mains power supply
01 = mains power cable 2 m, shockproof plug
only at 230 V/50 or 60 Hz
99 = without mains power cable (Standard)
10. Voltage/frequency
01 = 115V / 50 Hz
02 = 115V / 60 Hz
03 = 230V / 50 Hz (Standard)
04 = 230V / 60 Hz
05 = 3N 230V / 400V
E00
04500
PP
06
FP
KE
PP
99
99
03