EasyManua.ls Logo

Ecolab Elados EMP IV E00 - Technical Specifications Overview; Electrical Data

Ecolab Elados EMP IV E00
92 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
417101090_EMP_IV_E00_E10
- 54 -
Rev. 8-06.13
11.2 Dimensions
Fig. 11.1
capacity
type
measurement [mm]
A
C
C1
L
H1
H2
D
00140
133,5
170
174
392
280
216
1¼"
00210
133,5
170
174
392
280
216
1¼"
00450
142,5
190
194
412
303,5
263
2"
00630
142,5
220
225
412
318,5
293
2"
00750
142,5
220
225
412
318,5
293
2"
11.3 Technical specifications “Overview”
11.3.1 Electrical Data
Description
Pump type
01400
02100
04500
06300
07500
Supply voltage
230 V / 50/60 Hz ± 10 %
(special voltages on request)
max. power consumption I
N
115V 50/60 Hz
230V 50/60 Hz
3PE 400V 50 / 60 Hz
5.1 / 7.6 A
2.5 / 3.8 A
1.2 / 1.05 A
max. starting current I
A
( I
N
3,3)
115V 50/60 Hz
230V 50/60 Hz
3PE 400V 50 / 60 Hz
16.8 / 25.1 A
8.25 / 12.5 A
4.0 / 3.5 A
Motor Power 115V 50/60 Hz
230V 50/60 Hz
3PE 400V 50 / 60 Hz
0.3 kW
0.3 kW
0.37 kW
Fuse rating 115 V
230 V
12.5 A
6.3 A
Type of protection
IP 55
Breaking capacity at circuit with 24 V
Empty report output
stroke signal output
24 V 3 A AC/DC
24 V 0.3 A DC
Breaking capacity at circuit with 230 V
Empty report output
stroke signal output
230 V / 3 A AC/DC
connection according to VDE is not permitted