11.3.2 General datas – Standard pumps
Description
Max. metering backpressure [MPa (bar)] ***]
Number of strokes [1/min]
Metering quantity/stroke [ml] 50 Hz/60 Hz
Metering accuracy (see chapter 11.5)
Max. conveyable viscosity [mPas]
Permitted ambient temperature
Suction height [mWs] at 100 % stroke**
Max. permissible pre-pressure [MPa (bar)]
Noise level (DBA) in 1 m distance
(according to DIN EN 12639/ EN ISO 9614-2)
66.0
Recommended minimum diameter
Suction connector [ID mm]
Pressure connector [ID mm]
DN 20
DN 20
DN 25
DN 30
DN 30
11.3.3 Deviant datas - Pumps in the “Higher Pressures (HP)” versions
Description
Pump capacity [l/h]* / ***
Max. metering backpressure [MPa (bar)] ***
Metering quantity/stroke [cm³]
* all data relate to water at 20 °C
** Suction heights with clean, moistened valves at 100 % metering stroke and max. stroke frequency
*** At a mains power frequency of 60 Hz, the delivery capacity increases by 20 %, while the metering backpressure decreases by 20 %.
11.4 Materials
Pump head: PP, optional PVDF, stainless steel 1.4571
Diaphragm: PTFE-EPDM-compound diaphragm
Gaskets: FPM (Viton B), optional EPDM, Kalrez
Valve ball: Ceramic, glass, optional stainless steel 1.4401, PTFE
Valve spring: Hastelloy C4
Housing: PPO / AL
Colour: Blue RAL 5007
Special versions available on request.
11.5 Metering rates
The reproducible metering accuracy is approx. ± 3 % at a minimum 30% stroke length under
invariable conditions.
Due to the characteristics of the pump, higher output can be produced until the operating
temperature is reached.
Accurate metering can be achieved by observing the following points:
a) All metering output data refer to measurements with water at 20 °C as well as a constant
supply voltage and a warmed-up operating condition of the metering pump.
b) If there is pre-pressure (max. 0.8 bar) on the suction side, the pressure difference
between the suction and the pressure sides must be at least 0.1 MPa (1 bar). The water
column on the metering pump must be protected by an appropriate valve arrangement.
NOTE
A pressure maintaining valve or a metering value is not an absolutely hermetically
sealing shutoff device.
ATTENTION
Metering stroke adjustment may only be performed with the pump running if the stroke
adjusting screw is enabled.