EasyManua.ls Logo

Ecolab LMI 02 - Technical Data; Casing Specifications; Measuring Cell Specifications

Ecolab LMI 02
145 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
417102012_LMI02.doc - 88 - Rev. 9-07.08
11 Technical Data
11.1 Casing
Model: Wall mounted
Dimensions: 184 x 223 x 82 mm (W x H x D)
Weight: Approx. 3 kg
Degree of protection: IP 65 in acc. with DIN 40050
Protection class: I
Housing ducts: 5 cable gland M16x1.5
11.2 Measuring cell
Model: Oval shape streamlined, with 8 mm measuring channel diameter
Material: Model: PEEK
(polyether ether ketone approved by German Federal Health Office
(BGA) and Food and Drugs Administration (FDA)
Model: PP (Polypropylene)
Dimensions: 39 x 50 mm (D x H)
Resistance to pressure: PN = 10 bar at 20°C
(see also pressure/temperature curve)
Temperature stability: Max. 130°C (PEEK) short time
Max. 90°C (PP) short time
Chemical resistance: Resistant to inorganic acids and lye and to additives in a
application concentration range of 0…. 3 wt..-%
Temperature probe:
NTC resistor (R25 = 214 kΩ) in stainless-steel immersion shell
Reaction time of
temperature sensor in
conductivity probe:
Approx. 30 s (90 % value)
Material of immersion shell: V4A, 1.4571
Sealing element: O-ring, EPDM 281
Length of connecting cable: 0.2 m (with 3 m, 6 m and 20 m extension cables, can be extended
up to max. 20 m)
Cable type: 7-pole special measuring cable with round connector M12
Measuring cable connector: - fixed on sensor side
- plug-in type with 7-pole round connector M12 on instrument side
11.3 Conductivity control
11.3.1 Conductivity measurement
Measuring principle: Induction principle
Measuring frequency: Approx. 10 kHz
Measuring ranges: 10 mS/cm = 20 mA
20 mS/cm = 20 mA
100 mS/cm = 20 mA
200 mS/cm = 20 mA (set ex-works!)
Selection of measuring
range:
Under MEASURING RANGE in the CONFIGURATION
FUNCTIONS menu
Conductivity display: mS/cm display with decimal point
Measuring accuracy: +/- 2 % of final value
Reproducibility: +/-1 % of final value

Table of Contents

Related product manuals