Export of operating data and deletion of operating data
To export the operating data, a USB stick must be placed in the USB port of the LMI03.
Data is saved using the following ASCII formatting:
<alarm data>
start; [timestamp],count; [alarmcount]
[timestamp]; [alarmnumber]; [on/off]
...
</alarm data>
<operation data>
[timestamp];[conductivity];[temperature];[SP1];[SP2];[PM];[ALM]
...
</operation data>
Legend
<...>: Section start
</...>: End of section
[timestamp]: Format "YY
-MM-DD hh:mm:ss"
[alarmcount]: Number of alarms since start
[alarm number]: See
Ä
Chapter 9.2 ‘Fault messages’ on page 69
[on/off]: 1 Alarm on; 0 Notification
[conductivity]: Conductivity value, decimal value
[temperature]: Decimal value
[SP1]: Output SP1 (0/1)
[SP2]: Output SP2 (0/1)
[PM]: Output for pre-proportioning (0/1)
[ALM]: Output Alarm (0/1)
USB stick inserted in the LMI03
Starting point: ‘USB Export’ screen (80)
Ä
Chapter 7.1 ‘Initial start-up’ on page 43
1.
Select ‘Export Product Data
è (83) and confirm with .
2.
Confirm the export with .
ð
‘Delete Operating Data
can be selected