13 Decommissioning, disassembly, environmental protection
Personnel:
n
Operator
n
Mechanic
n
Service personnel
n
Specialist
Protective equipment:
n
Protective gloves
n
Chemical-resistant protective gloves
n
Protective eyewear
n
Safety shoes
DANGER!
Risk of injury due to the disregard of the specified personal protective
equipment (PPE)!
For all disassembly work, please respect the use of the PSA which is specified
on the product data sheet.
13.1 Decommissioning
DANGER!
The procedures described here may only be carried out by skilled personnel as
described at the start of the chapter
, this may only be done using PPE.
The procedure for decommissioning is as follows:
1. Before carrying out any work, first isolate the electrical supply completely and secure
it against being switched on again.
2. Relieve interior pump pressure and line pressure in the metering system.
3. Drain metering medium from the entire system without leaving any residue.
4. Drain and remove operating fluids and consumables.
5. Remove the remaining processing materials and dispose of them in an
environmentally friendly way
.
Decommissioning, disassembly, environmental protection