INSTRUCTIONS MANUAL
-44-
EDIT GAS CHARGE MODE
Select the connection mode:
- HP to fill the refrigerant only from the HP service port,
- LP to fill the refrigerant only from the LP service port,
- HP+LP fill the refrigerant from both HP and LP service ports
START PROCEDURE
After selected all the procedure data, press ENTER to continue
PROCEDURE will start, and the following screen will be displayed:
Connect and open the coupling connected to the A/C system, then press ENTER, press ESC
to return back
Oil will be injected, then if previously selected the UV will be injected :
When completed, the system will go on to charging with the preset quantity of refrigerant.
DD/MM/YY XX:XX PM
UV INJECTION
0 ml/ 0%
STOP
OIL INJECTION
Connect and open HP and LP couplings
To A/C system and press ENTER
ENTER
ESC
DD/MM/YY XX:XX PM
RECOVERY/RECYCLE
DD/MM/YY XX:XX PM
OIL INJECTION
0 ml/ 0%
STOP
OIL INJECTION