Note:
When the maximum wind speed of the last 4s is >=5m/s, the wind speed is
detected by 1s; when the maximum wind speed of the last 4s is >=3m/s and
less than 5m/s, the wind speed is detected by 2s; when the maximum wind
speed of the last 4s is <3m/ s, the wind speed is detected by 4s.
The wind speed reading will be a real-time value (The latest sampling data
will be reporting to the receiver).
The wind gust reading will be the max wind speed in the past 28s.
When the wind speed is lower than 5m/s, the dispersion of wind direction
will increase.
-10°C – 60°C (14°F - 140°F)
Barometric pressure range
300 – 1,100 hPa (8.85 – 32.5 inHg)
Barometric pressure accuracy
± 3 hPa in 700 – 1,100 hPa range
Barometric pressure resolution
Sensor reporting interval
Table 8: Indoor sensor specification
2 x AA 1.5 Alkaline batteries (not included)
1 x AA 1.5V LR6 Alkaline (not included), or
1 x AA 1.5V Lithium battery (not included)
Solar panel (built-in): 6.5V/4mA
Anemometer sensor
(backup)
2 x AA 1.5V Lithium battery (not included)
Table 9: Power specification