EasyManuals Logo
Home>ECTIVE>Inverter>CSI Series

ECTIVE CSI Series User Manual

ECTIVE CSI Series
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #61 background imageLoading...
Page #61 background image
ECTIVE CSI & SSI Series 59
Additional possible errors of inverter with integrated charger
Symptom Possible cause Solution
charger does not work parameters of input volta-
ge are outside of tolerance
check voltage and fre-
quency of input source
charger only supplies low
current
low input voltage
one or several batteries are
not connected / defect
use the right AC voltage
check all connections
charging does not function
despite shore power
connection
1. one or several batteries
defect
2. battery fuse defect
3. battery cable defect or
damaged
1. charger defect
1. check battery, change if
necessary
2. check fuse, change if
necessary
3. check cable, change if
necessary
4. contact producer/dealer
Caution!
Immediately eliminate error sources!
Make sure that error sources are eliminated. Multiple restarts due to unsolved errors can
destroy the inverter.
Especially prevent short circuits and polarity reversals because they can destroy the
device despite protection.