    April VelasquezAug 7, 2025
    What to do if my EKOM Medical Equipment compressor does not start?
    • J
      Joy RuizAug 7, 2025
      If your EKOM Medical Equipment compressor isn't starting, there are several potential causes: * Check if the mains breaker in the distribution system is switched off and turn it on, if needed. * Verify the power supply to ensure there's current in the pressure switch. * Replace the fuse if it is defective. * Tighten any loose wire terminals. * Replace the power cord if it is defective. * If the motor winding is interrupted or the thermal protection is damaged, replace the motor. * A defective capacitor should be replaced. * Replace any jammed piston or other damaged parts. * Change the pressure switch if it does not switch on.
  • A
    Autumn DavisAug 12, 2025
    Why does my EKOM Medical Equipment compressor often switch on?
    • W
      William JosephAug 12, 2025
      Your EKOM Medical Equipment compressor might be switching on frequently due to: * Air leakage from the pneumatic distribution system. To resolve this, inspect the pneumatic distribution system and seal any loose connections. * Leakage of the check valve. Try cleaning the check valve, replacing the sealing, or replacing the check valve.
  • N
    Nicole CollierAug 15, 2025
    What does it mean if the red indication lights are on for my EKOM Medical Equipment, indicating overheating?
    • S
      Steven JacksonAug 16, 2025
      If the red indication lights are on, indicating overheating in your EKOM Medical Equipment, possible causes include: * A dirty air intake filter, which should be cleaned or replaced. * Dirty filter inserts, which should be replaced with new ones. * Cooling fans not working, in which case the fans or a faulty thermo-switch should be replaced. * The unit being in a hot, unventilated area, requiring you to relocate the unit.
  • H
    Hannah WolfeAug 20, 2025
    Why is the operation of my EKOM Medical Equipment compressor extended?
    • A
      Ashley StephensonAug 20, 2025
      The extended operation of your EKOM Medical Equipment compressor may be due to: * Air leakage from the pneumatic distribution system, which requires checking the system and sealing any loose connections. * Worn out piston rings, which should be replaced. * Dirty filter inserts, which should be replaced.
  • J
    Jamie PowellAug 25, 2025
    How to fix noisy compressor (knocking, metal noises) in EKOM Medical Equipment?
    • J
      Joshua GarzaAug 25, 2025
      If your EKOM Medical Equipment compressor is making knocking or metal noises, it could be due to: * Damaged piston bearing or bearing on motor - replace the damaged bearing. * Loose (cracked) belt of the air pump hanger - replace the damaged hanger.
  • S
    Scott GarciaAug 28, 2025
    What to do if water is coming out of the outlets of my EKOM Medical Equipment?
    • M
      melissabrockAug 28, 2025
      If water is coming out of the outlets of your EKOM Medical Equipment, it is likely due to a functionless water trap. Try cleaning or replacing the water trap to resolve this issue.
  • Z
    zmartinSep 2, 2025
    What should I do if the humidity indicator is out of the green zone on my EKOM Medical Equipment?
    • M
      Margaret RussellSep 2, 2025
      If the humidity indicator on your EKOM Medical Equipment is out of the green zone, it could be caused by: * Leakage of air from the pneumatic distribution system. Inspect the pneumatic distribution system and seal any loose connections. * Large consumption of compressed air. Ensure you do not exceed the maximum flow specified in the technical data.