85Installation Manual
Appendix / Technical Specifications (AC)
Product Model
PP2-
AC-10/15/20-9600
PP2-
AC-10/15/20-8600
PP2-
AC-10/15/20-7600
PP2-
AC-10/15/20-7000
PP2-
AC-10/15/20-6000
PP2-
AC-10/15/20-5000
DC INPUT / BATTERY
Rated Charge / Discharge 50 A / 50 A
Maximum Charge /
Discharge
50 A / 50 A
DC Voltage Range 80-495
Battery Capacity (Range) 10 to 20 kWh
Battery Types Supported Lithium-ion (LFP)
DC Circuit Breaker Yes
DC Fuse on Plus Terminal Internal Fuse, not field replaceable
EFFICIENCY
Battery Charge/discharge
to AC Max. Eciency
96.6%
CEC Eciency 96.1%
OPERATIONAL FEATURES
AND MODES
Islanding Neutral Forming Transformer
Back-up (default) Ye s
Self Consumption Yes
Prioritized Charging from
Renewables
Yes
Grid Support - Zero Export Yes
Time-Of-Use Grid Export Yes
Genset Integration No
Grid Support/Demand
Response
Yes
Home current monitoring
(L1 & L2 CTs)
Yes
Over Current Protection Yes
Short Protection Yes
Over Voltage Protection Yes
Battery Reverse Polarity
Protection
Yes
ADDITIONAL AND
OPTIONAL FEATURES
Supported Communication
Interfaces
WiFi & Cellular
System Monitoring and
Network Communications
Cloud-Based Dashboard
Interface Protocol Proprietary
Loads Disconnect Isolation Yes
Inverter Bypass Switch Automatic
Rapid Shutdown
functionality for NEC 2014
690.12
External option
Arc Fault Protection (Type
1) for NEC 2011 690.11
compliance
Yes
Insulation Resistance
Detection
Yes
Revenue Grade Data,
ANSI C12.
Optional
NEMA 3R Enclosure Standard