EasyManua.ls Logo

Electrolux 5000 Series - Center Spray Arm and Upper Rack Manifold; Main Delivery Tube

Electrolux 5000 Series
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
SERVICE & DISASSEMBLY
CENTER SPRAY ARM AND UPPER RACK MANIFOLD
1. Remove upper rack and place rack upside down on
a flat surface.
2. Place blade of a very thin putty knife between
retaining ring and center spray arm. Lightly twist
knife to lift arm from retaining ring. (See Figure 30)
3. Remove manifold from rack by compressing tube
retainer clips and sliding tube backwards to clear
front mount. Reverse this procedure to reattach
manifold.
4. To reinstall arm, place both halves of retaining ring
onto manifold. Place center spray arm over retaining
clips and press into place.
5. After replacing rack in tub, reinstall rail end caps.
MAIN DELIVERY TUBE
1. To gain access to main delivery tube, cabinet will need to be removed. See
section on cabinet removal for detailed instructions.
2. Place dishwasher on its back. Loosen and remove clamp-holding tube from
inline heater.
3. Set dishwasher upright to remove nozzle from rear inside of tub. This
unscrews counterclockwise.
4. Remove tube from tub.
5. Reverse procedure to reinstall. Be sure to check gasket on upper end of tube
before tube end is placed into tub.
Figure 30
Putty knife between spray arm and retaining ring
Figure 31
Center rack manifold with retaining ring and
center spray arm arm

Table of Contents

Related product manuals