17. Troubleshooting Based on Alarm Codes
E41
E41: Door Opened at Cycle Start
E41
Door open.
E42
E42: Door Open Sensing Error
E42
Door Lock or Wiring or Sensing Circuit on Main Board failure.
Checks to perform:
WARNING
Check that all the connectors are correctly
inserted.
Check for any foreign object blockage on Door
Switch?
Clean and repeat the diagnostic cycle to check
for any further alarms.
Check for any obstacle in the door opening and
closing?
Remove the obstacle and repeat the diagnostic
cycle to check for any further alarms.
NO
Check if the Door Switch wiring terminals connected
properly?
Y
E
S
Check the continuity between terminals of Door
Switch (in closed condition). Is the continuity there?
YES
N
O
Check if the Dryer door is open?
Close the Door and repeat the diagnostic cycle
to check for any further alarms.
Y
E
S
Replace the Electronic Control Board and repeat the
diagnostic cycle to check for any further alarms.
Make the connections proper and repeat the
diagnostic cycle to check for any further alarms.
Change the Door Switch and repeat the
diagnostic cycle to check for any further alarms.
NO
YES
YES
N
O
N
O