48
E53
E53: Drum Motor Centrifugal Switch Error
E53
Motor Centripetal Switch, Electronic Control Board defective, or Wiring defective.
Checks to perform:
E54
E54: Drum Motor Sensing Error
E54
Electronic Control Board defective.
Checks to perform:
WARNING
Check that all the connectors are correctly
inserted.
WARNING
Check that all the connectors are correctly
inserted.
Check if the wiring between Electronic Control Board
and Motor is proper. Is the continuity there?
Y
E
S
Check if the Centripetal Switch of Motor is working
mechanically (stuck in open or closed position)?
Y
E
S
Replace the Electronic Control Board and repeat the
diagnostic cycle to check for any further alarms.
Replace / Repair wiring and repeat the
diagnostic cycle to check for any further alarms.
Replace the Motor and repeat the diagnostic
cycle to check for any further alarms.
NO
NO
Replace the Electronic Control Board and repeat the diagnostic cycle to check for any further alarms.
Troubleshooting Based on Alarm Codes

Table of Contents